NAPCO Gemini P1664 Security System Working- USED.
INCLUDES MAIN PANEL, TWO MOTION DETECTORS, KEYPAD.
WORKING WHEN REMOVED.
FEATURES
8 Hardwire/Wireless Zones on board Up to 64 zones with multiplex expansion including 2 two 2-wire fire zones With multiplexing, can accommodate up to 64 EOL zones (from custom alpha keypads or multiplex modules) EZ Programming2 More comprehensive, menu-driven programming for all zones plus test timer. Up to 64 user codes Up to 4 areas 3 on-board outputs, up to16 external relay outputs (RM3008s). Up to 2 NAPCO helically-filtered, crystal-control RF receivers Interior bypass group with programmable automatic interior bypass 400 event log Auto Arm Uses up to 7 of any of the Classic/RP-, K-Series or DK-Door Style Stay & Away keypads Programmable telephone line cut supervision with delay 3 Keypad panics (F, P, A) Supports all major communicator formats, including: 4/2, SIA, 4+2 and Point ID, plus pager Backup/double/split reporting; three 20-digit telephone numbers Dynamic battery test Reports alarms, restores and troubles by zone. 2 programmable entry delay times Chime by zone 8 EOL burglary zones programmable for area, E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning , etc. Multiplex Expandability with GEM EZM4/8 or GEM EZM8 zone expansion modules Quickloader up/downloading, including unique unattended method Choice of RF receivers Partitioning by area Event log with open/close suppression Event log viewable at keypad (total log, burglar alarm log, fire alarm log, system trouble log, o/c log) Cellphone-style keypad programming of zone descriptions ( text) Programmable 50Hz Clock Setting Programmable Daylight Savings Time Programmable Security Bypass (code required for bypass) Un-Bypassing while disarmed (code required) Temperature Display at Keypad (-30 to 600C Celsius or -22 to 1400F Fahrenheit) with optional GEM-TEMP64 Indoor/Outdoor Temperature Sensor (Note: Keypad Temperature Display replaces Date on Display and is for use with custom alphanumeric keypads, only, i.e., DK1, K1, RP1) Programmable High/Low Temperature Alarm Reporting (requires feature enabled; zone 6) 24 Hour day zone trouble Programmable Swinger Shutdown (2 or 3 activations – selectable) Zone Anding/Cross Zoning (Grouping of zones in which sequential zone activation is required to generate an alarm)
SPECIFICATIONS Input Power:
16.5-18.0 VAC via Class 2 Plug-In 20VA, 40VA or 50VA Transformer Loop Current:
3mA; 5mA for 2-wire smoke-detector zones Loop Resistance:
300 Ohm max.; 50 Ohm for 2-wire smoke detector zones Alarm Voltage Output:
1; Programmable Negative Outputs: 2 Auxiliary Power Output:
11.7-12.5 VDC Remote Power Output:
12 VDC regulated Combined Standby Current
- See WI1501 UL Listings & Compliances:
Household Burglar Alarm System Units: UL1023
Household Fire Warning System Units: UL985
Security Industry Association (SIA) False Alarm Reduction Standard CP-01